Hot water & Heating Equipment
  • home
  • >
  • Product Info
  • >
  • Hot water & Heating Equipment
Hot Water Generator

THS,THSS

Making it possible to use a large amount of hot water at the peak load and having automatic operating system to minimize temperature variation, it will supply hot water optimally under any circumstances.
Forced circulation type, less heating time
Stably supplies a large amount of hot water instantly as temperature variation of upper/lower part of hot well storage tank.
Easy to manage and repair the heat exchanger repair
Excellent heat transfer performance (two times better than that of bare tube)
Powerful Self Cleaning effect will always maintain the initial efficiency.
Self-absorption for heat deflection and thermal stress enables prolonged tube life.
Requires small installation space and weight is relatively light.
Siemens automatic valve is attached for a stable water supply. (Optional)
THS Specifications
(Based on steam pressure of 2kg/㎠, Hot Water design condition of 5~60℃)
Model Unit
THS-10 THS-15 THS-20 THS-30 THS-40 THS-50 THS-60 THS-80 THS-100 THS-125 THS-150 THS-200 THS-250 THS-300
1,000 1,500 2,000 3,000 4,000 5,000 6,000 8,000 10,000 12,500 15,000 20,000 25,000 30,000
55,000 82,500 110,000 165,000 220,000 275,000 330,000 440,000 550,000 687,500 825,000 1,100,000 1,375,000 1,650,000
Option : Siemens (SKD 62VVF)
Option : Siemens (ACX 36)
Option : Siemens (QAE 2120)
850 1,050 1,200 1,330 1,400 1,540 1,640 1,870 1,980 2,200 2,290 2,620 2,660 2,700
1,520 1,520 1,520 1,820 2,280 2,280 2,430 2,430 2,730 2,730 3,040 3,040 3,800 4,560
2,480 2,575 2,640 2,995 3,485 3,540 3,730 3,825 4,170 4,260 4,610 4,745 5,520 6,295
5/5 5/5 5/5 5/5 5/5 5/5 5/5 5/5 5/5 5/6 5/6 5/7 5/7 5/7
5/5 5/5 5/6 5/7 5/7 5/8 5/8 5/9 5/9 5/10 5/11 6/12 6/12 6/13
5/5 5/5 5/6 5/6 5/6 6/7 6/7 7/8 7/9 8/10 8/10 9/11 9/12 9/12
6/8 8/8 8/9 9/10 9/11 10/12 10/13 12/14 12/15 14/17 14/18 16/20 16/20 17/20
5/7 6/7 7/8 7/9 8/9 8/10 9/11 10/12 10/13 12/14 12/15 14/17 14/17 14/17
8/10 10/12 11/14 12/15 13/16 14/18 15/19 17/21 18/22 20/25 21/26 24/30 24/30 24/30
50 80 80 80 80 80 80 80 100 100 100 100 125 125
50 50 50 50 50 50 80 80 80 80 80 80 100 100
25 25 40 40 40 40 50 65 65 65 80 80 100 100
25 25 32 32 32 32 32 40 40 40 40 40 50 50
25 25 25 32 32 32 40 40 50 50 50 50 65 65
1005 1005 1007 1007 1010 1010 1507 1510 1513 2010 2013 2510 2513 3010
40×0.2 40×0.2 40×0.2 40×0.2 50×0.25 50×0.25 50×0.25 50×0.25 65×0.6 65×0.6 65×0.6 65×0.6 80×2.2 80×2.2
Tank
Body
Amount of Water Supply ℓ/hr
Rated Heating Value Kcal/hr
Control Valve  
Controller
Temperature Sensor
Size Diameter (D) mm
Length (L) mm
Height (H) mm
Thickness 3 /6
kg/㎠
Shell mm
End Plate mm
8/10
kg/㎠
Shell mm
End Plate mm
12/15
kg/㎠
Shell mm
End Plate mm
Connection
Bore
Diameter
Hot Water A
Return Water A
Steam A
Trap (Option) A
Safety Valve A
Heat Exchanger (THP) Model
Circulation Pump (Φ×kW) Size x kW
Scroll bar >>
  • Integrated- and removable- type as well as horizontal and vertical type is optional.
  • It is based on the material 304. (Material 316L is optional)
  • Thickness is subject to change depending on material.
  • Spiral Tube is applied to the heat exchanger.
  • Siemens automatic valve, control, and the trap is optional.
  • To facilitate disassembly and operation, keep the clearance of 1,000 mm or more.
  • Deal with the automatic control system after getting training from our C/S staff.
  • The above specification table can be unexpectedly changed in order to improve performance.