The other Boiler
  • home
  • >
  • Product Info
  • >
  • The other Boiler
Super Mini Boiler

DMI

It is possible to maximize the boiler efficiency by installing economizer depending on customer choice. (Optional)
It is eco-friendly, producing NOx under 40ppm. (optional)
The responsiveness to water quality is high.
Its installation space is rather small compared to that of conventional flue smoke tube type boiler.
DMI Specifications
Gas, Light Oil, Heavy Oil Type
Model Unit
DMI-50 DMI-80 DMI-100 DMI-150 DMI-200 DMI-250 DMI-300 DMI-350 DMI-400 DMI-450 DMI-500
500 800 1,000 1,500 2,000 2,500 3,000 3,500 4,000 4,500 5,000
1G 1.5G 2G 2.5G 3G 3.5G
7 ( Option : 10, 12, 14, 16 )
90
8 12 13 17 22.5 29 33.5 44 50 57 63
2.9 3.1 3.2 3.3 4.1 5.7 5.8 6.4 7.7 8 8.2
0.56 0.73 0.81 0.96 1.14 1.44 1.64 2.17 2.41 2.54 2.72
36.6 58.6 73.3 109.9 146.6 183.2 219.8 256.5 293.1 329.7 366.4
34.7 55.5 69.4 104.0 138.7 173.4 208.1 242.8 277.5 312.1 346.8
35.7 57.2 71.4 107.2 142.9 178.6 214.3 250.1 285.8 321.5 357.2
24.6 39.4 49.3 73.9 98.5 123.2 147.8 172.5 197.1 221.7 246.4
15.9 25.5 31.9 47.8 63.8 79.7 95.7 111.6 127.6 143.5 159.5
32.2 51.5 64.4 96.6 128.8 161.1 193.3 225.5 257.7 289.9 322.1
11.2 18.0 22.4 33.7 44.9 56.1 67.3 78.5 89.8 101.0 112.2
29.1 46.6 58.3 87.4 116.6 145.7 174.9 204.0 233.2 262.3 291.5
Forced Draft Fan (Blast Type)
Fluid Power Injection Type
Hi-Low-Off (Three Stage System) Hi-Middle-Low-Off (Four Stage System)
Gas Ignition
Light Oil Ignition
Westco Pump Vertical Multistage Centrifugal Pump
1.5x2 1.5x2 2.2x2 2.2x2 2.2x2 2.2x2 4x2 4x2 4x2 4x2 4x2
1.5 2.2 2.2 3.7 5.5 7.5 7.5 11 11 11 15
6 6 6 6 9 9 9 9 9×2 9×2 9×2
0.4 0.4 0.4 0.4 0.75 0.75 0.75 0.75 1.5 1.5 1.5
25(40) 25(50) 25(50) 40 40 50 50 50 50 50 50
20 20 20 20 20 20 20 20 20 20 20
40 50 50 65 80 80 80 80 100 100 125
25 25 25 25 40 40 40 40 40 40 40
400×200 400×200 400×200 400×250 450×300 570×300 650×300 700×300 750×300 900×350 900×350
250 300 300 350 350 400 440 470 500 540 560
2450 2700 2800 3050 3310 3570 3670 4295 4190 4250 4550
1960 2030 2040 2060 2175 2360 2420 2540 2600 2705 2730
2290 2340 2380 2425 2570 2645 2830 2910 3140 3170 3240
Boiler
Body
Rated Evaporation kg/hr
Hot Water Gcal/hr
Max-Working Pressure kg/㎠
Efficiency %
Heating Surface
Weight Ton
Contained Water Ton
Fuel
consumption
Heavy Oil (Bunker C Oil) kg/hr
Light Oil kg/hr
LNG N㎥/hr
LPG+AIR N㎥/hr
Propane
(LPG)
N㎥/hr
kg/hr
Butane
(LPG)
N㎥/hr
kg/hr
Burner Combustion System Gas Type
Oil Type
Ctrl. System  
Ignition System Gas Type
Oil Type
Power Consumption Feed Water Pump Type
kW×Quantity
Blower Motor kW
Oil Heater kW
Oil Pump kW
Connection
Bore
Diameter
Gas Inlet A
Oil Inlet A
Main Steam Outlet A
Feed Water Inlet A
Installation
Summary
Exhaust Port mm
Flue Duct mmØ
Length mm
Width mm
Height mm
Scroll bar >>
  • Fuel consumption was based on the net heating value.
       (Light Oil: 10,300 kcal/㎏,Heavy Oil(Bunker C Oil): 9,750 kcal/㎏, LNG: 11,000 / 10,000 kcal/N㎥, LPG + AIR: 15,400 / 14,500 kcal/N㎥, Propane: 24,350 / 22,400 kcal/N㎥, Butane: 31,840 / 29,500 kcal/N㎥)
  • Supply gas pressure was based on the inter-stage pressure (2,000 ~ 4,000 mmAq)
  • Gas diameter in parentheses ( ) was based on low-pressure. (200mmAq)
  • Calorie generation was based on the steam pressure of 10kg/㎠, steam enthalpy of 663.7 kcal/kg, and feed water temperature of 20℃.
  • Boiler efficiency is under rated load based on the net heating value.
  • Boiler efficiency and calories can be reduced depending on site conditions as well as measurement error.
  • The above specification table can be unexpectedly changed in order to improve performance.