The other Boiler
  • home
  • >
  • Product Info
  • >
  • The other Boiler
New Super Mini Boiler

DMH

High efficiency (more than 92%) boiler with the heat pipe type air pre-heater attached.
It is possible to maximize the boiler efficiency by installing economizer depending on customer choice. (Optional)
It is eco-friendly, producing NOx under 40ppm. (optional)
The responsiveness to water quality is high.
Its installation space is rather small compared to that of conventional flue smoke tube type boiler.
DMH Specifications
Gas, Light Oil Type
Model Unit
DMH-50 DMH-80 DMH-100 DMH-150 DMH-200 DMH-250 DMH-300 DMH-350 DMH-400 DMH-450 DMH-500
500 800 1000 1500 2000 2500 3000 3500 4000 4500 5000
1G 1.5G 2G 2.5G 3G 3.5G
7 ( Option : 10, 12, 14, 16 )
92
8 12 13 17 22.5 29 33.5 44 50 57 63
2.9 3.1 3.2 3.3 4.1 5.7 5.8 6.4 7.7 8 8.2
0.56 0.73 0.81 0.96 1.14 1.44 1.64 2.17 2.41 2.54 2.72
33.9 54.3 67.9 101.8 135.7 169.6 203.6 237.5 271.4 305.4 339.3
34.9 55.9 69.9 104.8 139.8 174.7 209.7 244.6 279.6 314.5 349.5
24.1 38.6 48.2 72.3 96.4 120.5 144.6 168.7 192.8 216.9 241.0
15.6 25.0 31.2 46.8 62.4 78.0 93.6 109.2 124.8 140.4 156.0
31.5 50.4 63.0 94.5 126.0 157.6 189.1 220.6 252.1 283.6 315.1
11.0 17.6 22.0 32.9 43.9 54.9 65.9 76.8 87.8 98.8 109.8
28.5 45.6 57.0 85.5 114.1 142.6 171.1 199.6 228.1 256.6 285.1
Forced Draft Fan (Blast Type)
Fluid Power Injection Type
Hi-Low-Off (Three Stage System) Proportional System
Gas Ignition
Light Oil Ignition Gas Ignition
Heat - Pipe Type
GA-5 GA-8 GA-10 GA-15 GA-20 GA-25 GA-30 GA-35 GA-40 GA-45 GA-50
0.18 0.2 0.25 0.3 0.35 0.4 0.45 0.5 0.77 0.79 0.82
1.5×2 1.5×2 2.2×2 2.2×2 2.2×2 2.2×2 4×2 4×2 4×2 4×2 4×2
2.2 3.7 3.7 5.5 7.5 11 11 11 15 15 15
0.4 0.4 0.4 0.4 0.75 0.75 0.75 0.75 1.5 1.5 1.5
25(40) 25(50) 25(50) 40 40 50 50 50 50 50 50
20 20 20 20 20 20 20 20 20 20 20
40 50 50 65 80 80 80 80 100 100 125
25 25 25 25 40 40 40 40 40 40 40
250×285 300×410 300×435 350×480 400×565 400×605 430×625 430×665 480×725 480×725 464×775
250 300 300 350 350 400 440 470 500 540 560
2650 2950 3050 3430 3690 3855 3960 4410 4470 4530 4805
1510 1640 1650 1780 1980 2070 2190 2240 2420 2440 2540
2305 2340 2390 2465 2730 2855 2995 3070 3205 3340 3510
Boiler
Body
Rated Evaporation kg/hr
Hot Water Gcal/hr
Max-Working Pressure kg/㎠
Efficiency %
Heating Surface
Weight Ton
Contained Water Ton
Fuel
consumption
Light Oil kg/hr
LNG N㎥/hr
LPG+AIR N㎥/hr
Propane
(LPG)
N㎥/hr
kg/hr
Butane
(LPG)
N㎥/hr
kg/hr
Burner Combustion System Gas Type
Oil Type
Ctrl. System  
Ignition System Gas Type
Oil Type
Air
Pre-Heater
Type  
Model  
Weight Ton
Power
Consumption
Feed Water Pump kW×Quantity
Blower Motor kW
Oil Pump kW
Connection
Bore
Diameter
Gas Inlet A
Oil Inlet A
Main Steam Outlet A
Feed Water Inlet A
Installation
Summary
Exhaust Port mm
Flue Duct mmØ
Length mm
Width mm
Height mm
Scroll bar >>
  • Fuel consumption was based on the net heating value.
      (Light Oil : 10,300 kcal/㎏, LNG: 11,000 / 10,000 kcal/N㎥, LPG + AIR: 15,400 / 14,500 kcal/N㎥, Propane: 24,350 / 22,400 kcal/N㎥, Butane: 31,840 / 29,500 kcal/N㎥)
  • Supply gas pressure was based on the inter-stage pressure (2,000 ~ 4,000 mmAq)
  • Gas diameter in parentheses ( ) was based on low-pressure. (200mmAq)
  • Calorie generation was based on the steam pressure of 10kg/㎠, steam enthalpy of 663.7 kcal/kg, and feed water temperature of 20℃.
  • Boiler efficiency is under rated load based on the net heating value.
  • Boiler efficiency and calories can be reduced depending on site conditions as well as measurement error.
  • The above specification table can be unexpectedly changed in order to improve performance.