Once Through Boiler
  • home
  • >
  • Product Info
  • >
  • Once Through Boiler
Once Through Boiler

SAJ

All function is controlled by a simple switch manipulation.
It does not require a license as well as an inspection.
It is a compact product that requires a small installation space.
SAJ Specifications
Gas, Light Oil, Heavy Oil Type
Model Unit
SAJ-10P SAJ-20P SAJ-30P SAJ-40P SAJ-50P SAJ-60P
100 200 300 400 500 600
64,370 128,740 193,110 257,480 321,850 386,220
7 ( Option : 10 )
88
2.6 3.9 4.9 4.92 4.95 4.99
0.4 0.5 0.75 0.9 0.95 1.1
30 55 64 76 78 80
7.1 14.2 21.3 28.4 35.5 42.6
7.3 14.6 21.9 29.3 36.6 43.9
5.0 10.1 15.1 20.2 25.2 30.3
3.3 6.5 9.8 13.1 16.3 19.6
6.6 13.2 19.8 26.4 33.0 39.6
2.5 5.0 7.4 9.9 12.4 14.9
6.4 12.9 19.3 25.8 32.2 38.7
0.75 0.75 0.75 1.5 1.5 1.5
0.125 0.25 0.25 0.75 0.75 0.75
0.875 1 1 2.25 2.25 2.25
3¢*220V,380V(60Hz)
ON-OFF(Two Stage System) High-Low-OFF(Three Stage System)
Forced Draft Fan (Blast Type)
High Voltage Electric Spark
20 25 25 40 40 40
15 15 15 15 15 15
20 25 25 32 32 40
20 20 20 25 × 20 (Suction × Discharge)
20 20 32 32 40 40
25 25 25 25 25 25
150 200 200 250 250 250
200 250 250 300 300 300
1,200 1,230 1,420 1,500 1,500 1,600
760 760 860 800 800 910
1,590 1,930 2,010 2,235 2,235 2,245
Boiler
Body
Rated Evaporation kg/hr
Heat Capacity Kcal/hr
Max-Working Pressure kg/㎠
Efficiency %
Heating Surface
Weight Ton
Contained Water
Fuel
consumption
Light Oil kg/hr
LNG N㎥/hr
LPG+AIR N㎥/hr
Propane
(LPG)
N㎥/hr
kg/hr
Butane
(LPG)
N㎥/hr
kg/hr
Power
Consumption
Feed Water Pump kW
Blower Motor kW
Total Pwr. Consumption kW
Sources of Electricity
Ctrl.
System
Combustion System  
Burner Type  
Ignition System
Connection
Bore
Diameter
Gas Inlet A
Oil Inlet A
Main Steam Outlet A
Feed Water Inlet A
Safety Valve A
Drain A
Installation
Summary
Flue Duct mm¢
Stack mm¢
Length mm
Width mm
Height mm
Scroll bar >>
  • Fuel consumption was based on the net heating value.
    (Light Oil: 10,300 kcal/kg, LNG: 11,000 / 10,000 kcal/Nm3, LPG + AIR: 15,400 / 14,500 kcal/Nm3, Propane: 24,350 / 22,400 kcal/Nm3, Butane: 31,840 / 29,500 kcal/Nm3)
  • Calorie generation was based on the steam pressure of 10kg/cm2, steam enthalpy of 663.7 kcal/kg, and feed water temperature of 20℃.
  • Boiler efficiency is under rated load based on the net heating value. (optional feature for high-efficiency boiler)
  • Boiler efficiency and calories can be reduced depending on site conditions as well as measurement error.
  • Identical low and inter-stage pressure, gas valve specification
  • Governor should be installed for inter-stage pressure.
  • The above specification table can be unexpectedly changed in order to improve performance.